Model 570 Flush Tip Pressure Transmitter

5x proof, 4-20 mA output, Blender Pressure Measurement

The Model 570 Flush Tip – Zero Cavity design offers an Isolated sensor assembly that virtually eliminates installation torque effect and is able to withstand pressure spikes up to 5x proof pressure and 20x burst pressure.

Features

 All Stainless Steel construction
 Many Options available
 High Overpressure Applications
 IP-67 Rated
              

Description

The Model 570 Flush Diaphragm Pressure Transmitter is designed to meet the rigorous demands placed on pressure transmitters used for well-servicing applications including manifold charge and high-pressure pump suction pressure measurements.

Features of the Model 570 flush diaphragm pressure transmitter include:

  • Flush Tip Diaphragm (Zero Cavity Design)
  • Patented* Solid Stainless-Steel Diaphragm Technology
  • Isolated Sensor Design virtually eliminates torque effect
  • Withstands 5 times Proof Pressure at 0-1,000 psis range
  • Withstands 20 times Burst Pressure at 0-1,000 psis range
  • High Accuracy (≤ +/-0.50% FSO)
  • IP67 rating (Fully welded and sealed housing)
  • Hazardous Approval Options Available

Minimizing the torque effect on the diaphragm has eliminated the need to adjust the instrument after installation. The ability to withstand pressure spikes up to 5 times the 0-1,000 psis range extends the life of the transmitter when cavitation is a risk in the system. The patented pressure sensor diaphragm technology has resulted in a very stable unit with the high performance and data integrity needed for blending in acidizing, cementing and fracturing applications.

*US Patent 9,851,272 B2

570ft datasheet

Full Scale Pressure Ranges
0-100, 150, 160, 200, 250, 300, 400, 500,750, 1,000 PSIS
Accuracy (RSS)
≤±0.50% FSO (Includes BFSL, Hysteresis and Repeatability by RSS)
Compensated Temperature Range
70°F to 170°F (21°C to 77°C)
Operating Temperature Range
-40°F to 185°F (-40°C to 85°C)
Storage Temperature Range
-40°F to 250°F (-40°C to 120°C)
Long Term Stability (%FSO)
≤±0.5% FSO per 6 months
Thermal Effect on Zero
≤±2% FSO per 100°F Typical
Thermal Effect on Span
≤±2% FSO per 100°F Typical
Output Signal
4-20 mA
Supply Voltage
8-28 Vdc
Power Supply Regulation
<±.05% FSO per volt
Load Impedance
926 Ohms maximum at 28 volts DC
Circuit Protection
Reverse polarity protected, CE marked
RFI / EMI
CE EMC compliant as per IEC EN 61326-1 and EN 61326-2-3 Annex BB
Voltage Spike Protection
Withstand 1000 volt spike per EN 61000-4-5
Insulation Resistance
<5 nS
Response Time
<2 mSec for 10-90% of final value
Electrical Connection
Bendix PT02E-10-6P, mates PT06E-10-6S (SR) (BH option)
Pin Outs
Pin A               + Power / Signal
Pin B                – Power / Signal
Pin C                No connection
Pin D               No connection
Pin E                AC Ground
Pin F                No connection
Shell                Case Ground